MAD150-300W Series AC-DC Isolated Power Supply Modules - Mingxin Technology
I. model
single path
model | Input voltage (Vac) | Input voltage range (Vac) | Output voltage (Vdc) | Output current (A) | Ripple (mv) | Efficiency (Typ) |
MAD150-220S05 | 220VAC | 176-264 | 05VDC | 30A | 100 | 85% |
MAD240-220S12 | 220VAC | 176-164 | 12VDC | 20A | 120 | 87% |
MAD240-220S24 | 220VAC | 176-264 | 24VDC | 10A | 200 | 88% |
MAD300-220S28 | 220VAC | 176-264 | 28VDC | 10.7A | 280 | 88% |
MAD300-220S48 | 220VAC | 176-264 | 48VDC | 6.25A | 300 | 89% |
Dual-path
model | Input voltage (Vac) | Input voltage range (Vac) | Output voltage (Vdc) | Output current (A) | Ripple (mv) | Efficiency (Typ) |
MAD150-220D05&12 | 220VAC | 176-264 | 05&12VDC | 10&8A | 100&120 | 83% |
MAD150-220D05&24 | 220VAC | 176-264 | 05&24VDC | 8&4A | 120&200 | 83% |
MAD150-220D05&48 | 220VAC | 176-264 | 05&48VDC | 10&2A | 100&300 | 83% |
IIFeatures
1 | Input wideband noise filtering |
2 | Input surge current suppression circuit |
3 | Compliant with UL1950 and IEC950 safety regulations |
4 | Beautiful design |
5 | Terminal block wiring method |
Unless otherwise specified, all parameters are tested under the following conditions: ambient temperature 25°C, nominal input voltage, and purely resistive nominal load.
IIIInput characteristics
Rating (VAC) | Voltage range (VAC) |
220 VAC | 176-264 VAC |
IVOutput characteristics
power | 150-300W |
Output voltage | 5-48VDC |
Output current | 3-40A |
Voltage regulation (main circuit) | ±0.5% |
Load regulation (main route) | ±0.5% |
voltage accuracy | ±2% |
Current limiting point | 120%(Typ) |
V. Protective characteristics
1 | Input undervoltage protection |
2 | Output short circuit protection |
3 | Over-temperature protection |
4 | Output overcurrent protection |
General characteristics
Operating frequency | 100-200KHz |
Insulation resistance | 200MΩ |
Isolation voltage value
Input-Output | >1500VAC/1 min leakage current <5mA |
Input - Shell | >1500VAC/1 min leakage current <5mA |
Output - Housing | >500VDC/1 min |
Main road - secondary road | >500VDC/1 min |
Environmental characteristics
Operating case temperature | (Industrial products) | -25 – +85℃ |
(Army I) | -40 – +85℃ | |
(Army II) | -55 – +85℃ | |
Storage temperature | (Industrial products) | -45 – +105℃ |
(Army I) | -55 – +105℃ |
WEExternal dimensions and pin definitions
|
VII. REFERENCE PICTURES
|